Mitsubishi Ducted Systems – FDUA Series | 1 Phase

$3,440.25$6,121.18 Incl. GST

The FDUA series of ducted air conditioning systems are a quiet and discreet climate solution for your entire home. Ranging from 10.0kW up to 20kW, the FDUA series incorporates a range of convenient features and functions including high power mode, silent mode, eco mode and several timer and scheduling functions.


POWER: Single Phase | AVAILABLE IN: Reverse Cycle

CAPACITIES: 10.0kW | 12.1kW | 12.5kW | 14.0kW | 16.0kW

Key Features
FDUA Specifications
Key Features
Key Features
  • HIGH POWER MODE FOR RAPID COOLING & HEATING
  • WEEKLY & SLEEP TIMERS
  • SILENT OPERATION
  • DRY OPERATION TO REDUCE HUMIDITY
  • ECONOMY MODE TO REDUCE POWER CONSUMPTION
FDUA Specifications
ABCDEFGHIJKLMNOPQRSTUVWXY
1
1 phaseSetFDUA100AVNPWVHFDUA100AVNAWVHFDUA125VNPWVHFDUA125AVNPWVHFDUA125AVNXWVHFDUA140AVNXWVHFDUA160AVNXWVH3 phaseSetFDUA100AVSAWVHFDUA125AVSXWVHFDUA140AVSXWVHFDUA160AVSAWVHFDUA200AVSAWVHFDUA250AVSAWVH
2
IndoorFDUA100VHFDUA100VHFDUA125VHFDUA125VHFDUA125VHFDUA140VHFDUA160VHIndoorFDUA100VHFDUA125VHFDUA140VHFDUA160VHFDUA200VHFDUA250VH
3
OutdoorFDCA100VNP-WFDCA100VNA-WFDC125VNP-WFDCA125VNP-WFDCA125VNX-WFDCA140VNX-WFDCA160VNX-WOutdoorFDCA100VSA-WFDCA125VSX-WFDCA140VSX-WFDCA160VSA-WFDCA200VSA-WFDCA250VSA-W
4
Power source (Outdoor Unit)1 Phase 240V 50HzPower source (Outdoor Unit)3 Phase 380-415V 50Hz
5
*Operation dataNominal Capacity (Range)Cooling T1kW10 (2.1 -10.2)10.0 (4.0-11.2)12.1 (5.0-12.1)12.1 (5.0-12.1)12.5 (5.0-14.0)14.0 (5.0-14.5)16.0 (5.0-17.0)*Operation dataNominal Capacity (Range)Cooling T1kW10.0 (4.0-11.2)12.5 (5.0-14.0)14.0 (5.0-14.5)16.0 (6.9-20.0)20.0 (6.9-28.0)23.5 [ 6.9(Min.) - 28.0(Max.)]
6
Heating H110 (1.7 - 10.4)11.2 (4.0-12.5)12.1 (4.0-13.3)12.1 (4.0-13.3)14.0 (4.0-17.0)16.0 (4.0-18.0)18.0 (4.0-21.0)Heating H111.2 (4.0-12.5)14.0 (4.0-18.0)16.0 (4.0-18.0)18.0 (5.5-22.4)22.4(5.5-31.5)28.0 [ 5.5(Min.) - 31.5(Max.)]
7
Heating H27.6107.97.914.215.515Heating H21014.215.516.12121.1
8
Power consumptionCooling T1kW2.993.053.853.853.834.025Power consumptionCooling T1kW3.053.834.024.685.787.7
9
Heating H12.572.873.283.283.684.195Heating H12.873.684.194.65.447.7
10
Maximum power consumptionkW4.466.44.754.756.135.777.1Maximum power consumptionkW10.27.667.2611.211.211.2
11
Running currentCooling T1A13.214.716.216.21717.822Running currentCooling T1A4.76.46.77.59.112
12
Heating H111.41413.813.816.318.622Heating H14.46.26.97.58.612
13
Inrush current, maximum currentA5, 195, 265, 205, 205, 295, 305, 30Inrush current, maximum currentA5, 175, 185, 195, 245, 275, 27
14
EERCooling T13.343.283.143.143.263.483.16EERCooling T13.283.263.483.423.463.16
15
COPHeating H13.893.93.693.693.83.823.6COPHeating H13.93.83.823.914.123.67
16
Sound power level (JIS C9612)OutdoordB(A)68697373686969Sound power level (JIS C9612)OutdoordB(A)696869737373
17
Sound pressure level (JIS C9612)IndoordB (A)P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:48 Hi:47 Me:43 Lo:38P-Hi : 48 Hi : 47 Me : 43 Lo : 41Sound pressure level (JIS C9612)IndoordB (A)P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:48 Hi:47 Me:43 Lo:38P-Hi:48 Hi:47 Me:43 Lo:41P-Hi:52 Hi:50 Me:47 Lo:45P-Hi : 52 Hi : 50 Me : 47 Lo : 45
18
Outdoor56555757545454Outdoor555454585858
19
External dimensions (HxWxD)Indoormm398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1450x930398 × 1450 × 930External dimensions (HxWxD)Indoormm398x1150(+86)x650398x1150(+86)x650398x1450x930398x1450x930379x1600(+85)x893379x1600(+85)x893
20
Outdoor750 × 880(+88) × 340845x970x370845x970x370845x970x3701300x970x3701300x970x3701300 × 970 × 370Outdoor845x970x3701300x970x3701300x970x3701505x970x3701505x970x3701505x970x370
21
Net weightIndoorkg52525252526666Net weightIndoorkg545266668888
22
Outdoor57777373979797Outdoor789999145145145
23
Supply air connectionmm348x898348x898348x898348x898348x898298x1064298x1064Supply air connectionmm348x898348x898298x1064298x1064250x1450250x1450
24
Return air connectionmm348x898348x898348x898348x898348x8982 X φ4002 X φ400Return air connectionmm348x898348x8982 X φ4002 X φ400250x1450250x1450
25
External Static Pressure (max)Pa200200200200200150150External Static Pressure (max)Pa200200150150200200
26
AirflowIndoor (Cooling)l/sP-Hi:650 Hi:600 Me:550 Lo:483P-Hi:650 Hi:600 Me:550 Lo:483P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:1000 Hi:867 Me:733 Lo:600P-Hi : 1000 Hi : 867 Me : 733 Lo : 683AirflowIndoor (Cooling)l/sP-Hi:650 Hi:600 Me:550 Lo:483P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:1000 Hi:867 Me:733 Lo:600
P-Hi:1000 Hi:866 Me:733 Lo:683
P-Hi:1333 Hi:1200 Me:1067 Lo:933P-Hi:1333 Hi:1200 Me:1067 Lo:933
27
Indoor (Heating)P-Hi : 1000 Hi : 867 Me : 733 Lo : 600Indoor (Heating)
P-Hi:1000 Hi:866 Me:733 Lo:600
28
Refrigerant (R32)Quantitykg1.73.32.252.25444Refrigerant (R32)Quantitykg3.3445.15.15.1
29
Pre charged to pipe length
m15301515303030
Pre charged to pipe length
m303030303030
30
Installation dataRefrigerant pipingLiquid linemm**Ø6.35**Ø6.35Ø9.52Ø9.52Ø9.52Ø9.52Ø9.52Installation dataRefrigerant pipingLiquid linemmØ9.52Ø9.52Ø9.52Ø12.7Ø12.7Ø12.7
31
Gas lineØ15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Gas lineØ15.88Ø15.88Ø15.88Ø22.22 , Ø25.4 or Ø28.58Ø22.22 , Ø25.4 or Ø28.58Ø22.22 , Ø25.4 or Ø28.58
32
Connection methodFlare ConnectionConnection methodFlare ConnectionLiquid : Flare / Gas : Brazing
33
Maximum pipe (one way) lengthm30503030100100100Maximum pipe (one way) lengthm50100100**70**70**70
34
Max vertical height diff. between O.U. and I.U.m
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Max vertical height diff. between O.U. and I.U.m
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
35
ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
36
Safety Pan (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)NANASafety pan (Optional)UA-SP2-E (Optional)NANANANA
37
Motion Sensor (Optional)LB-KIT2Motion Sensor (Optional)LB-KIT2
38
Demand response (AS4755)NoYesNoYesYesYesYesDemand response (AS4755)YesYesYesYesYesYes
39
Outdoor air temperature (upper, lower limits)CoolingC-15 to 46-15 to 50-15 to 46-15 to 46-15 to 50-15 to 50-15 to 50Outdoor air temperature (upper, lower limits)CoolingC-15 to 50-15 to 50-15 to 50-15 to 50-15 to 50-15 to 50
40
HeatingC-15 to 20-20 to 20-15 to 20-15 to 20-20 to 20-20 to 20-20 to 20HeatingC-20 to 20-20 to 20-20 to 20-20 to 20-20 to 20-20 to 20
41
42
* Operation data are are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page xxx* Operation data are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Pagexxx
43
44
**Reducer set Ø9.52 --> Ø6.35 is included in the outdoor unit as accessory for FDCA100VNP-W.** Maximum 70m(Gas piping:φ25.4 or φ28.58), Maximum 35m(Gas piping:φ22.22)
45
***Max.30m (Outdoor unit is higher & Outdoor air temperature > 43˚C)
*** Max.30m (Outdoor unit is higher & Outdoor air temperature > 43˚C)